Developer: White lid (used directly in the development slot).
Replenisher: Red lid (added gradually).
Ratio: Developer : Replenisher = 1 : 4.
Development Slot Volume: ~38 liters.
Initial Setup Steps:
Add 2 drums of Developer directly.
Gradually add 8 drums of Replenisher (do not add all at once).
Replacement Cycle: Every 7–10 days, then begin cycling.
Dilution Ratio: 1 drum Replenisher + 2 liters water (matches Developer concentration).
Follow the same steps as above after dilution.
Temperature: 22°C – 24°C.
Time: 25 ± 5 seconds.
Dynamic: 80–100 ml/m².
Static: 80 ml/h.
Sleep Mode: 80 ml/h.
Good tolerance.
Excellent dot reproduction.
Slow chemical density attenuation.
Low volatility.
Usage: Pour directly into the developer tank.